Shielded Flat Festoon Cable for Cranes
$0.00
Applications:
Overhead and gantry cranes with festoon cable systems
Hoists and lifting equipment
Moving power and control circuits in industrial material-handling equipment
Crane installations requiring a flexible flat cable with shielding for electromagnetic interference control
Use in accordance with the cable’s rated voltage, travel conditions, and installation requirements
Structure
Flat ribbon cable construction with fine-stranded Class 5 copper conductors and shielding.
The insulation is oil-resistant and flame-retardant. The outer sheath is oil-resistant, flame-retardant elastic PVC. Core identification: black cores; a yellow/green protective conductor is included where specified in the ordered construction.
Key Specifications
• Type: YFFBP
• Shielding: Present
• Rated voltage: 300/500 V for conductor cross-sections ≤1.5 mm²;
450/750 V for cross-sections >1.5 mm²
• Test voltage: 2,500 V for cross-sections ≤1.5 mm²;
3,000 V for cross-sections >1.5 mm²
• Operating temperature: −15 °C to +70 °C
• Minimum bending radius: 10 × cable outer diameter
• Reference standards: GB/T 3956-2008, IEC 60228, EN 50214
• Dimensions and approximate mass: Refer to the specification table for each configuration.